CZ EN

Cooling systems

CAG TT VZ

air cooled units

AIR COOLED units are used for tempering and cooling of molds and heating systems. The rated cooling capacity of these devices is from 5kW to 300kW. The devices can be mobile or static, for cooling individual appliances and their groups. Aggregates are for temperatures of + 10 ° C to + 40 ° C at ambient temperatures up to 45 ° C. They have integrated water tanks with a volume of 25 to 600 (l).

 

TT-5.500 E

  • Air-cooled mobile device with a heater in the water circuit
  • Closed water circuit
  • Rated cooling capacity 5 kW
  • Actual cooling capacity at an air temperature of 25 ° C and a water temperature of 20 ° C - approx. 3.2 kW


   Datasheet TT-5500 E PDF
 

 

TT-14.500 H

  • Air-cooled mobile device with a heater in the water circuit
  • Closed water circuit
  • Rated cooling capacity 14 kW

Actual cooling capacity at an air temperature of 25 ° C

  • at a water temperature of 10 ° C - approx. 5.1 kW
  • at a water temperature of 20 ° C - approx. 6.9 kW

It is also available in a water-cooled version of the TT-14.500 H / WK

   Datasheet TT-14500 H PDF
 

 

TT-28.500

  • Air-cooled mobile device with a heater in the water circuit
  • Closed water circuit
  • Rated cooling capacity 28 kW

Actual cooling capacity at an air temperature of 25 ° C

  • at a water temperature of 10Â ° C - approx. 10.6 kW
  • at a water temperature of 20 ° C - approx. 15 kW

It is also available in a water-cooled version of the TT-28.500 WK

   Datasheet TT-28.500 PDF
 

 

TT-54.500

  • Air-cooled mobile device with a heater in the water circuit
  • Closed water circuit
  • Rated cooling capacity 54 kW
Actual cooling capacity at an air temperature of 25 ° C
 
  • at a water temperature of 10 ° C - approx. 21.5 kW
  • at a water temperature of 20 ° C - approx. 30 kW
It is also available in a water-cooled version of the TT-54.500 WK
 

   Datasheet TT-54.500 PDF
 

 

TT-108.000

  • Air-cooled device
  • Closed water circuit
  • Rated cooling capacity 108 kW
Actual cooling capacity at an air temperature of 25 ° C
 
  • at a water temperature of 10 ° C - approx. 43 kW
  • at a water temperature of 20 ° C - approx. 60 kW
It is also available in a water-cooled version of the TT-108,000 WK


   Datasheet TT-108.000 PDF           
 

 

TT-216.000

  • Air-cooled device
  • Closed water circuit
  • Rated cooling capacity 216 kW
Actual cooling capacity at an air temperature of 25 ° C
 
  • at a water temperature of 10 ° C - approx. 86 kW
  • at a water temperature of 20 ° C - approx. 118 kW
It is also available in a water-cooled version of the TT-216,000 WK


   Datasheet TT-216.000 PDF
 

 

TT-300.000

  • Air-cooled device designed for operation with a separate water tank
  • Closed water circuit without refrigeration compressor
  • Rated cooling capacity 300 kW


   Datasheet TT-300.000 PDF
 

 

AIR COOLED WATER COOLING AND TEMPERING UNITS

TT-13502 E

  • Dual-circuit tempering and water cooling device for use from 10 ° C to 90 ° C
  • Two independent circuits - one for temperatures of 10 - 90 ° C, the other for temperatures of 10 - 40 ° C
  • Heating capacity 2 x 6 kW, nominal cooling capacity 8 kW


   Datasheet TT-13502 E PDF